Application | Hospital |
Model | OSCAR VAPORISER |
Automation Grade | HIGH |
Body Material | COPPER BRASS S.S. |
Capacity Ml | 230 ML |
Color | WHITE |
Filler Type | POUR FILL |
Design Pressure Kg Sq Cm | N.A. |
Weight | 6.8 kg approx |
Flow Range Ml Per Min | COMPLETE ANAESTHETIC RANGE |
Display Type | GLASS INDICATOR |
Dimension | 110X215X230 mm (WXDXH) |
Condition | New |
Dial Control | 0-8% vol |
Gas Flow Rate | 0.5 - 15 lpm |
Operation Altitude | Max. 8000 ft |
Temperature | 18 - 35 Degree Celsius |
We are actively involved in providing an extensive range ofOscar Anaesthesia Vaporizer. Due to high demand, professionals develop these products in varied specifications that meet on client’s demand.
Details:
The Anesthesia Major Meets With The Safety Features Recommended By The International Standards Organization. Long Oxygen Flow Meter Tubes Accurately Calibrated. Oxygen Flow Is Received Downstream Of Other Gas, Being The Preferred Gas. Incorporate One Vaporizer HalothaneTwo Pairs Of Yokes With Regulators & Gauges Colors Coded For Oxygen.To Minimize Backflow Of Gases Non-return Cum Pressure Relief Valve Is ProvidedEmergency Oxygen Flush Button Cum Outlet At Table Level.
Features:
Structure
Square Tubular Electro Statically Powder Coated Steel Sections.
Table Top
Stainless Steel.
Drawer
Extra Large One Storage Drawer.
Cylinder Yokes
Pin-Indexed Gas Specific Dual Oxygen Yokes.
Regulators
For Higher Efficiency And Reliability Each For Oxygen
Nitrous Cut-off
Nitrous Cut-off System Is Provided .
Oxygen Failure Warning Device
Pneumatic Device Which Activates Audible Alarm When Oxygen Supply Pressure falls 215 Kpa.
Rotameters
Antistatic Colour Coded Non Inter Changeable Long Rotating Bobbin Flow Meters Accurately Calibrated.
Oxygen - 100 Ml / Min. To 10 Litres/min.
Oxygen Flow Control Is On Left Side Of Flow meter As It Is Preferred Gas.
Vaporisers
One Halothane vaporizer Supplied As Standard.
Non-return Cum Pressure Relief Valve
To Minimises Risk Of Back flow Of Gases, Non Return Value Provided
Emergency Oxygen
Oxygen Flush Button With Out-let At Table Level 4.22 KPa X 100
Accessories
One Schrader Type Self Sealing Oxygen Out-let For Ventilator/flowmeter Can Be Used As Pipe Line Inlet Extended Rear Platform For Two 10 Liter Capacity Cylinder,Circle absorber Can Be Securedly Mounted On The Left Side Of The Main Frame.
Breathing Attachment
Standard Magill's Circuit.
Mobility
Antistatic Large Diameter Caster Wheels With Ball Bearings. Front Casters have Brakes.
Change Over
lever System Provided For Change Over From Open To Close Circuit And Vise Versa.
Item Code | VAPORIZER |
Delivery Time | 1 WEEK |
Production Capacity | 30PM |
Packaging Details | BOX |
Copyright © 2018 activemedical Designed By Newwebmotion